FILLING THE BOILER
NOTE: if the sequence indicated below does not take place, see the chapter entitled "TROUBLESHOOTING". After having completed the preliminary operations:
Press the On switch on the right side of the machine; the keyboard lights up. The machine automatically loads the water into the boiler (initial time approximately three minutes). When the water has reached the correct level, the heating of the water starts signalled by the resistance warning light coming on.
NOTE: the machine has an electronic level valve so it automatically feeds in water to the boiler as needed to restore the level.
NOTE: the machine safety system shuts down the machine after the pump has been running steadily for approximately 1,5 minutes (this prevents the pump from overheating). In this case, switch off the machine using the main switch and switch on again to complete the first filling.
Whilst functioning, the keyboard is backlit.
The resistance warning light comes on when it is necessary to heat the water in the boiler and when the level in the boiler is sufficient.
Wait until the heating light goes off, indicating that the water has reached the desired temperature.
NOTE: At the start of the day’s activities and in any case, if there are an pauses of more than 8 hours, then it is necessary to change 100% of the water in the circuits, using the relevant dispensers.
NOTE: In case of use where service is continuous, make the above changes at least once a week.